Daikin 2MXS-N Series Engineering Data page 278

Multi-split type air conditioners, r410a, inverter
Hide thumbs Also See for 2MXS-N Series:
Table of Contents

Advertisement

EDUS121503A
Indoor air
Combination
temp.
(Capacity)
EDB (°F)
CTXS07L +
60.8
FDXS09L +
64.4
FDXS12L +
FTXS18L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FDXS09L +
64.4
FDXS12L +
CDXS18L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FTXS09L +
64.4
FTXS15L +
FTXS15L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FTXS09L +
64.4
FTXS15L +
CDXS15L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FTXS09L +
64.4
CDXS15L +
CDXS15L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FDXS09L +
64.4
FTXS15L +
FTXS15L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FDXS09L +
64.4
FTXS15L +
CDXS15L
68.0
70.0
71.6
75.2
CTXS07L +
60.8
FDXS09L +
64.4
CDXS15L +
CDXS15L
68.0
70.0
71.6
75.2
Multi-Split Type Air Conditioners 2/3/4MXS-N Series
5.0
14.0
TC
PI
TC
PI
TC
kBtu/h
kW
kBtu/h
kW
kBtu/h
22.72
2.40
27.29
2.53
31.87
22.16
2.43
26.74
2.55
31.31
21.60
2.46
26.18
2.58
30.75
21.29
2.47
25.87
2.60
30.44
21.04
2.48
25.62
2.61
30.19
20.48
2.51
25.06
2.63
29.63
22.05
2.14
26.49
2.25
30.92
21.51
2.16
25.94
2.27
30.38
20.96
2.19
25.40
2.30
29.84
20.66
2.20
25.10
2.31
29.54
20.42
2.21
24.86
2.32
29.30
19.88
2.23
24.32
2.34
28.75
24.12
3.07
28.98
3.23
33.84
23.53
3.11
28.39
3.26
33.24
22.94
3.14
27.79
3.30
32.65
22.61
3.16
27.46
3.32
32.32
22.34
3.17
27.20
3.33
32.05
21.75
3.21
26.60
3.37
31.46
23.45
2.85
28.17
3.00
32.89
22.87
2.89
27.59
3.03
32.31
22.30
2.92
27.02
3.06
31.74
21.98
2.94
26.70
3.08
31.42
21.72
2.95
26.44
3.10
31.16
21.14
2.98
25.86
3.13
30.58
22.72
2.52
27.29
2.65
31.87
22.16
2.54
26.74
2.67
31.31
21.60
2.57
26.18
2.70
30.75
21.29
2.59
25.87
2.72
30.44
21.04
2.60
25.62
2.73
30.19
20.48
2.63
25.06
2.76
29.63
23.45
2.84
28.17
2.98
32.89
22.87
2.87
27.59
3.02
32.31
22.30
2.90
27.02
3.05
31.74
21.98
2.92
26.70
3.06
31.42
21.72
2.93
26.44
3.08
31.16
21.14
2.97
25.86
3.11
30.58
22.72
2.67
27.29
2.81
31.87
22.16
2.70
26.74
2.84
31.31
21.60
2.73
26.18
2.87
30.75
21.29
2.75
25.87
2.88
30.44
21.04
2.76
25.62
2.90
30.19
20.48
2.79
25.06
2.93
29.63
22.05
2.32
26.49
2.43
30.92
21.51
2.34
25.94
2.46
30.38
20.96
2.37
25.40
2.49
29.84
20.66
2.38
25.10
2.50
29.54
20.42
2.39
24.86
2.51
29.30
19.88
2.42
24.32
2.54
28.75
Outdoor air temp. EWB (°F)
23.0
32.0
43.0
PI
TC
PI
TC
kW
kBtu/h
kW
kBtu/h
2.65
36.44
2.77
41.93
2.68
35.88
2.80
41.37
2.70
35.32
2.83
40.81
2.72
35.01
2.84
40.50
2.73
34.76
2.85
40.25
2.76
34.20
2.88
39.69
2.36
35.36
2.47
40.69
2.38
34.82
2.49
40.14
2.41
34.28
2.52
39.60
2.42
33.97
2.53
39.30
2.43
33.73
2.54
39.06
2.45
33.19
2.56
38.52
3.39
38.69
3.54
44.52
3.42
38.10
3.58
43.92
3.45
37.50
3.61
43.33
3.47
37.17
3.63
43.00
3.49
36.91
3.65
42.74
3.52
36.32
3.68
42.14
3.15
37.61
3.29
43.27
3.18
37.03
3.32
42.70
3.21
36.46
3.36
42.12
3.23
36.14
3.37
41.80
3.24
35.88
3.39
41.54
3.27
35.30
3.42
40.97
2.77
36.44
2.90
41.93
2.80
35.88
2.93
41.37
2.83
35.32
2.96
40.81
2.85
35.01
2.98
40.50
2.86
34.76
2.99
40.25
2.89
34.20
3.02
39.69
3.13
37.61
3.27
43.27
3.16
37.03
3.31
42.70
3.19
36.46
3.34
42.12
3.21
36.14
3.36
41.80
3.22
35.88
3.37
41.54
3.26
35.30
3.40
40.97
2.94
36.44
3.08
41.93
2.97
35.88
3.11
41.37
3.00
35.32
3.14
40.81
3.02
35.01
3.16
40.50
3.03
34.76
3.17
40.25
3.06
34.20
3.20
39.69
2.55
35.36
2.67
40.69
2.58
34.82
2.70
40.14
2.60
34.28
2.72
39.60
2.62
33.97
2.74
39.30
2.63
33.73
2.75
39.06
2.66
33.19
2.78
38.52
Capacity Tables
50.0
59.0
PI
TC
PI
TC
PI
kW
kBtu/h
kW
kBtu/h
kW
2.92
45.59
3.02
50.16
3.14
2.95
45.03
3.05
49.60
3.17
2.98
44.47
3.07
49.04
3.20
2.99
44.16
3.09
48.73
3.21
3.00
43.91
3.10
48.48
3.22
3.03
43.35
3.13
47.92
3.25
2.60
44.24
2.69
48.67
2.80
2.62
43.69
2.71
48.13
2.82
2.65
43.15
2.73
47.59
2.84
2.66
42.85
2.75
47.29
2.86
2.67
42.61
2.76
47.05
2.87
2.69
42.07
2.78
46.50
2.89
3.73
48.40
3.86
53.03
3.97
3.77
47.81
3.89
52.26
3.97
3.80
47.21
3.93
51.51
3.97
3.82
46.88
3.95
51.10
3.97
3.84
46.62
3.96
50.77
3.97
3.87
45.95
3.97
50.05
3.97
3.47
47.05
3.59
51.77
3.73
3.50
46.47
3.62
51.19
3.76
3.53
45.90
3.65
50.62
3.80
3.55
45.58
3.67
50.30
3.81
3.56
45.32
3.68
50.04
3.83
3.60
44.74
3.71
49.46
3.86
3.06
45.59
3.16
50.16
3.29
3.09
45.03
3.19
49.60
3.32
3.11
44.47
3.22
49.04
3.35
3.13
44.16
3.23
48.73
3.36
3.14
43.91
3.25
48.48
3.37
3.17
43.35
3.27
47.92
3.40
3.45
47.05
3.57
51.77
3.71
3.48
46.47
3.60
51.19
3.74
3.51
45.90
3.63
50.62
3.77
3.53
45.58
3.65
50.30
3.79
3.54
45.32
3.66
50.04
3.81
3.58
44.74
3.69
49.46
3.84
3.24
45.59
3.35
50.16
3.49
3.27
45.03
3.38
49.60
3.52
3.30
44.47
3.41
49.04
3.55
3.32
44.16
3.43
48.73
3.57
3.33
43.91
3.44
48.48
3.58
3.36
43.35
3.47
47.92
3.61
2.81
44.24
2.91
48.67
3.03
2.84
43.69
2.93
48.13
3.05
2.87
43.15
2.96
47.59
3.08
2.88
42.85
2.97
47.29
3.09
2.89
42.61
2.99
47.05
3.11
2.92
42.07
3.01
46.50
3.13
1