3.1
<KDT25N32, KDT25N50> Insulation Kit for High Humidity
Caution
This kit can be installed to the Ceiling mounted Built-in Type Air Conditioners.<Slim duct type>
When the Installation box for adapter PCB(KRP1BA101)is used together, mount this kit before Installation box.
It is recommended to mount this kit before installing the indoor unit.
Combination table
KDT25N32
FDXS09/12LVJU
Details of parts
1
Designation
Top plate insulation
A
Shape
Number of
1 pc.
pieces
Designation
5
Bottom plate insulation
A
Shape
Number of
1 pc.
pieces
Designation
7
Hanger (right) insulation
390
Shape
Slit
Number of
1 pc.
pieces
«
How to attach
<Procedure> Stick the insulations carefully according to the following procedures
and do not make a gap between the adjacent thermal insulations.
(1) Stick the top plate insulation T-1
(2) Cut off the side plate insulation
(3) Stick the side plate insulation S-1 to the indoor unit right side plate.
(4) Stick the side plate insulation S-1 to the indoor unit left side plate
without cutting off the area surrounded by the score.
(5) Stick the side plate insulation S-2 to the indoor unit left side plate.
(6) Stick the bottom plate insulation B-1 to the indoor unit bottom plate.
(7) Stick the chamber cover insulation C-1 to the indoor unit chamber cover.
(8) Stick the hanger (left) insulation H-2 and the hanger (right) insulation H-1
to the left and right hangers respectively.
(See the right figure for the sticking reference.)
S-2
H-2
S-1
Hanger bracket (left)
Side plate (left)
A
B-1
Options
Kit name
KDT25N50
CDXS15/18LVJU
T-1
2
Top plate insulation
A
Slit
Slit
(mm)
Kit name
A
KDT25N32
700
KDT25N32
KDT25N50
900
KDT25N50
KDT25N63
KDT25N63
1100
1 pc.
B-1
6
Chamber cover insulation
(mm)
A
Slit
Kit name
A
KDT25N32
704
KDT25N50
904
KDT25N63
1104
1 pc.
H-1
8
Hanger (left) insulation
(mm)
390
1 pc.
When moving the unit at or after opening, hold the unit by the hanger brackets.
Do not apply force to the refrigerant piping, drain piping or flange parts.
,
T-2 to the indoor unit top plate.
S-1
following the score.(See the right figure)
T-2
Side plate (right)
KDT25N63
T-2
3
Side plate insulation S-1
380
(mm)
(mm)
Score
Score
Slit
Kit name
A
700
900
1100
2 pcs.
C-1
(mm)
Slit
Kit name
A
KDT25N32
621
KDT25N50
821
KDT25N63
1021
H-2
9
Installation manual
(mm)
Slit
( This instruction )
1 pc.
»
Cut off the area shown with oblique lines and throw it away.
T-1
B
Hanger brackets (right)
C-1
S-1
H-1
Options for Indoor Unit
4
Side plate insulation S-2
240
(mm)
1 pc.
VRV model only
VRV and Room Air conditioners
KDT25N50, KDT25N63 model only
ARROW VIEW A
H-2
H-1
DETAIL B
DETAIL C
C: 3P131323-1E
4
C
645