EDUS121503A
Outdoor air
Combination
temp.
(Capacity)
EDB (°F)
FDXS12L +
68.0
FDXS12L +
77.0
FDXS12L +
FDXS12L
86.0
89.6
95.0
104.0
109.4
114.8
Symbols:
EWB
: Entering wet bulb temp.
EDB
: Entering dry bulb temp.
TC
: Total capacity
PI
: Power input
Multi-Split Type Air Conditioners 2/3/4MXS-N Series
57.2
60.8
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
34.83
2.72
36.40
2.78
33.25
2.89
34.82
2.94
31.67
3.06
33.23
3.12
31.03
3.14
32.60
3.19
30.08
3.26
31.65
3.31
25.79
2.56
26.89
2.56
20.19
1.77
20.95
1.77
12.55
0.98
12.97
0.98
Notes:
(°F)
1. Ratings shown are net capacities which include a deduction for indoor fan
(°F)
2.
3. TC and PI must be calculated by interpolation using the figures in the
(kBtu/h)
(kW)
4. Capacities are based on the following conditions.
5. Corresponding refrigerant piping length : 25 ft
Indoor air temp. EWB (°F)
64.4
67.0
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
37.97
2.83
38.75
2.86
36.38
2.99
37.17
3.02
34.80
3.17
35.58
3.20
34.17
3.25
34.95
3.28
33.22
3.37
34.00
3.39
27.97
2.56
28.50
2.56
21.68
1.77
22.05
1.77
13.38
0.98
13.58
0.98
motor heat.
shows max capacities and power input.
above tables. (Figures out of the tables should not be used for
calculation.)
Capacity Tables
71.6
75.2
TC
PI
TC
PI
kBtu/h
kW
kBtu/h
kW
41.10
2.94
42.67
2.99
39.52
3.10
41.08
3.16
37.93
3.28
39.50
3.34
37.30
3.36
38.87
3.41
36.35
3.47
37.92
3.53
30.05
2.56
31.05
2.56
23.12
1.77
23.81
1.77
14.17
0.98
14.55
0.98
C: 3D094022 ~ 3D094024
C: 3D094026 ~ 3D094029
C: 3D094030 ~ 3D094039
C: 3D094040 ~ 3D094049
C: 3D094050 ~ 3D094051
C: 3D094053 ~ 3D094059
C: 3D094060 ~ 3D094065
C: 3D094067 ~ 3D094069
C: 3D094070 ~ 3D094072
227
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents