3 Option Boards
3-2-6
How Option Boards Operate in Case of an Error
The tables below show how Option Boards operate if an error occurs.
Errors Not Related to Option Boards
Event level
Major fault level
Partial fault level
Minor fault level
Observation
Information
Errors Related to Option Boards
Event level
Option Board Configuration Veri-
fication Error
Unsupported Option Board
Mounted
Option Board Error
Analog Option Board Startup
Error
Analog Option Board Communi-
cations Error
3 - 14
Serial Communications
Option Board
No change.
Serial Communications Option Board
Host link function disabled when Host
Link (FINS) is selected.
Error generated at execution of a serial
communications instruction when Host
Link (FINS) is not selected.
---
---
NX-series NX1P2 CPU Unit Built-in I/O and Option Board User's Manual (W579)
Analog I/O Option Board
Load turned OFF for analog output.
Analog input values at error occur-
rence retained.
No change.
Analog I/O Option Board
Load turned OFF for analog out-
put.
Analog input value reset to 0.