Cellular Programming Options; System Options - DSC LE4000 Installation Manual

Lte universal wireless alarm communicator
Hide thumbs Also See for LE4000:
Table of Contents

Advertisement

C
The Programming Sections described in this document can be viewed at the SCW9055/
SCW9057 LCD. To start programming enter: [*][8][installer code] [851][# # # ], Where # # #
is the 3-digit section number referenced in this section. The Programming Worksheets at the
end of this document can be used to record the new values when programming changes have
been made from the default values.
Programming sections are accessed through using Connect24. Installers can review/record
programming Options at the panel.
NOTE: Cellular Programming Sections accessed through the panel are for display purposes
only. Configuration changes must be done using Connect24.
S
O
YSTEM
PTIONS
[004] Receiver Supervision Interval
Default (0087/135)
When receiver supervision is enabled (ON) in section [005], toggle option [3], the unit sends
heartbeats to Cellular Receiver 1 to test the communications path. Use this section to set the
interval time (in seconds) when heartbeats are sent to the receivers. Valid range 000A-FFFF
seconds. If the programmed value is less than (000A/10) seconds, supervision is disabled.
• Receiver Window: This is the supervision timeout that must be configured at the central
station receiver.
• Recommended Values: This is the recommended heartbeat interval that should be
programmed into the Communicator.
• For ULC installations, the Daily test transmission must be enabled over each available
communication channel sections [125] and [225]. When programming using Connect24,
the recommended intervals are programmed automatically when the required window is
selected.
[005] System Toggle Options
[2] Cellular Receiver 1 Supervised
Default (OFF)
ON: Cellular Receiver 1 is supervised and heartbeats are sent to Cellular Receiver 1 based on
the supervision interval programmed in section [004]. If ACK to heartbeat is not received, it is
retransmitted every 5 seconds. Failure to ACK 2 consecutive heartbeats resets the radio.
OFF: Cellular Receiver 1 is not supervised. When disabled, heartbeat is not sent to the
receiver. Supervisory trouble is indicated.
NOTE:
Cellular Receiver 2 cannot be supervised.
[3] Supervision Type
Default (OFF)
ON: Heartbeat 1 (Commercial Supervision). This supervision type is suitable for applications
where swap detection is required on the supervisory packet.
OFF: Heartbeat 2 (Residential Supervision). This supervision type is suitable for applications
where supervision of the communication path to the receiver is required. (no swap detection).
NOTE: Commercial supervision is more data intensive than residential supervision and must
only be used when required to meet the approval for the installation.
[6] Remote Firmware Upgrade
Default (ON)
ON: The Communicator module firmware can be remotely upgraded using the Cellular paths.
OFF: The Communicator module firmware cannot be remotely upgraded. Local firmware
upgrade is still possible.
[7] Alternate Test Transmissions
Default (OFF).
P
ELLULAR
ROGRAMMING
O
10
PTIONS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents