5

Service Parts Replacement

A. Blower Replacement
1. Combustion (Exhaust) Blower Replacement
a. Remove panel set and disconnect flue.
b. Pull appliance out onto the hearth.
c. Remove right access panel and then slide out right
side panel of appliance, held in place with 2 screws, to
expose the exhaust blower.
d. Disconnect the white and blue wires from the blower.
Remove blower mounting screws (not housing bolts),
Figure 25.2, from blower housing and remove blower.
The replacement blower is shipped with a housing. If
you do not need the housing, discard it. If you do need
to the replace the housing you will also need to replace
the gasket. See Service Parts starting on page 32 for
the part number.
e. Re-install in reverse order.
Figure 25.1
Housing Bolts
Blue Wire
White Wires
Figure 25.2
August 3, 2018
Exhaust Blower
Blower Mounting
Screws
7019-229G
2. Convection Blower Replacement
a. The blower is located at the bottom rear of the insert. If
an outside air kit is also installed, you will first need to
remove the outside air flange by removing the 2 screws
using a Phillips head screwdriver. You do not need to
remove the flex pipe from the flange.
b. Remove panel set and disconnect flue.
c. Pull appliance out onto the hearth.
d. Remove left access panel and then slide out left side
panel of appliance to expose the convection blower.
Loosen wing nut on the vacuum switch and remove
vacuum switch to allow room to remove the blower.
e. Disconnect the wires from the blower. The wires coming
from the wiring harness are purple & white and the
wires from the blower are black.
f.
The blower is held in place with a magnet. A wing
nut and plate are installed at the factory for shipping
purposes only. This can be removed once the appliance
is installed. Lift up blower from the magnet and remove.
g. Re-install in reverse order.
Blower
locator plate
Magnet attached to
bottom of blower
Figure 25.3
Santa Fe Pellet Insert
Wing nut & plate
installed for shipping
purposes only.
Discard
25