Download Print this page

Daikin FTK09NMVJU Service Manual page 15

Removal procedure, 9000/12000 btu/h class, indoor unit, inverter, wall mounted type, cooling only, heat pump
Hide thumbs Also See for FTK09NMVJU:

Advertisement

Si041552E
Step
5
Detach the indoor unit
from the installation
plate.
2. Remove the indoor heat
exchanger.
1
Unfasten the 2 hooks
and remove the piping
fixture on the back of
the indoor unit.
2
Slightly widen the
auxiliary piping.
3
Remove the 2 screws
on the left side and
unfasten the hook on
the rear side.
4
Unfasten the hook on
the right side and lift up
the indoor heat
exchanger.
Removal Procedure
Procedure
Piping fixture
Hook
Auxiliary piping
Hook
Indoor heat
exchanger
Indoor Heat Exchanger
Points
(R21849)
(R21035)
(R21036)
(R21037)
When reassembling the
indoor heat exchanger,
make sure that the hook is
fastened.
(R21850)
13