PCBs / Swing Motor
Step
4
Remove the connector
[S26] and release the
harnesses from the 3
hooks.
5
Unfasten the 4 hooks
and remove the control
PCB.
10
Procedure
Points
[S26]: display PCB
When reassembling, pass
the harness of the connector
[S26] under this hook and
the 3 wires.
3 wires
When reassembling, be sure
to fit the control PCB to the 4
projections.
Projection
(R21858)
Si041552E
Hook
(R21844)
Removal Procedure