Detailed Description of Maintenance-mode Functions

1.3.1 EEPROM Parameter Initialization (Maintenance mode 01, 91)

< Function >
This function initializes the parameters, user switches and worker switches settings registered in
the EEPROM, to the initial values. Entering Maintenance mode 01 initializes almost all of the
EEPROM areas, but entering Maintenance mode 91 does not initialize some areas, as listed
below.
Data item
Maintenance-mode functions
User switches
Firmware switches
Remote activation code
Assurance mode switch settings
Activity report
Station ID data
Outside line number
Telephone function registration
Speed dialing
Group dialing
Call transfer data
EEPROM customizing code
(4-digit)
< Operating Procedure >
(1) Press the 0 and 1 keys in this order to display "Maintenance 01" on the LCD (or press the 9
and 1 keys in this order according to your need to display "Maintenance 91") in the initial
stage of the maintenance mode.
(2) Press the Mono Start key.
The "PARAMETER INIT" appears on the LCD.
(3) Upon completion of parameter initialization, the machine returns to the initial stage of the
maintenance mode.
Maintenance mode
01
All of these will be
initialized.
This will not be initialized.
(Note that the first digit of the 4-digit code will be
initialized to "0." If the code is 1001, for example,
it will be initialized to 0001.)
5-5
91
These will be
initialized.
These will not be
initialized.
Confidential