Hoshizaki IM-21 Service Manual page 31

Self-contained cuber
Table of Contents

Advertisement

See the diagram on the right for layout of the
Controller Board.
VR:
Variable Resistor
No. 2 through No. 5 adjustable
K:
Connector
IC:
Integrated Circuit Chip
LED:
Light Emitting Diode
Indicator Lamp
TF:
Transformer
X:
Relay
RESET:
Reset Button
To check the operation of the
board, push the Reset Button only
during the freeze cycle.
Relay
X1 - Actuator Motor and Pump Motor
X2 - Hot Gas Valve and Fan Motor
X3 - Water Valve
X4 - Compressor
Control
VR2 - Defrost Control
VR3 - Backup Timer
VR5 - Cube Control
All the controls are factory-adjusted. Do not
change setting except when replacing the
board or if the setting has changed. Refer to
"[e] CONTROLS AND ADJUSTMENT."