2. WATER REGULATING VALVE - WATER-COOLED MODEL ONLY

The Water Regulating Valve is factory-adjusted. Do not adjust it except at replacement or
service. Adjust the valve setting, if necessary, as follows:
1) Attach a pressure gauge to high-side line, or prepare a thermometer to check Condenser
drain temperature.
2) Rotate the Adjust Screw using a flat blade screwdriver so that the pressure gauge shows
10 bar [IM-25WLE, IM-30WLE, IM-45WLE, IM-65WLE, IM-100WLE], 16 bar [IM-130WLE,
IM-130WME] or 19 bar [IM-240WME, IM-240WM2E], or the thermometer reads 38 - 40°C,
5 minutes after Freeze Cycle starts.
When the pressure or temperature exceeds the above, rotate the Adjust Screw
counterclockwise.
3) Check that the pressure or temperature holds.