A.6
Open spigots to drain product
until no product is visible through
the front door. Refi ll the bucket
with water as necessary.
NOTE
If the "Clean Time Exceeded" warning
is displayed on the IntelliTec2™, turn the
freezing cylinder on and off again to clear
the warning. Press the Clean button to
resume cleaning.
A.7
Remove the buckets to help
clear any remaining liquid in
the hoses.
Drain the water from the
freezing cylinders and press
the Clean and Pump buttons
to stop the augers.
A.8
Open the spigots to release
any pressure in the freezing
cylinders (machines with gate
style handles).
513713 REV.0
B. Disassemble Parts
U421-I2A & U431-I2A OPERATOR'S MANUAL
Section 2: Operation
A.9
Press and hold the Main
Freezer Power button for
three seconds to turn off
the power.
Before using the machine for the fi rst time, complete
machine disassembly, cleaning and sanitizing
procedures need to be followed. Routine cleaning
intervals and procedures must comply with the local
and state health regulations. Inspection for worn or
broken parts should be made at every disassembly
of the machine. All worn or broken parts should be
replaced to ensure safety to both the operator and the
customer and to maintain good machine performance
and a quality product. Check the wear line on the auger
fl ights on a regular basis and replace as needed.
Auger Flight Wear