Service & Maintenance
Service & Maintenance
• The unit is designed to give long life operation with minimum maintenance required. However, it should be regularly
Components
1. Remove any dust adhering to the fi lter by using a vacuum
cleaner or wash in lukewarm water (below 40°C) with a neutral
cleaning detergent.
Air Filter
2. Rinse the fi lter well and dry before placing it back onto the
(Indoor Unit)
unit.
3. Note: Never use gasoline, volatile substances or chemicals to
clean the fi lter.
1. Clean any dirt or dust on the grille or panel by wiping it with a
soft cloth soaked in lukewarm water (below 40°C) and a neutral
Indoor Unit
detergent solution.
2. Note: Never use gasoline, volatile substances or chemicals to
clean the indoor unit.
Condense Drain
1. Check the cleanliness and clean it if necessary.
Pan & Pipe
2. Check the condensate water fl ow.
Indoor Fan
Check if there is any abnormal noise.
1. Check and remove the dirt between the fi ns.
2. Check and remove any obstacles which hinder air fl ow through
Indoor / Outdoor
the indoor or outdoor.
Coil
3. Note: Avoid direct contact of any coil treatment material on the
plastic part. This may cause plastic part to deform as a result
of chemical reaction.
1. Check the running current and voltage for indoor and outdoor
unit.
Power Supply
2. Check the electrical wiring and tighten the wire onto the terminal
block if necessary.
No maintenance needed if refrigerant circuit remains sealed.
Compressor
However, check for refrigerant leak at joint and fi tting.
Indoor Models

1. Open the front panel

• Hold the panel at the recesses on the main unit
(2 recesses on right and left sides) and lift it until
it stops.

2. Remove the front panel

• While lifting the front panel further, slide it to the
right and pull it to the front side. The left rotating
shaft is detached. Slide the right rotating shaft to
the left and pull it to the front side to remove it.
3. Attach the front panel
• Align the right and left rotating shafts of the front
panel with the grooves and push them all the
way in.
• Gently close the front panel. (Push both ends
and the center on the front panel.)
36
• Disconnect from main supply before servicing the air conditioner.
checked and the following items should be given due attention.

Maintenance Procedures

Rotating
shaft
Period
At least once every 2
weeks.
More frequently if
necessary.
At least once every 2
weeks.
More frequently if
necessary.
Every 3 months.
If necessary.
Every month.
Every 2 months.
Every year.
Every 6 months.