Electrical Noise; P Recautions For I Nstallation; I Nstallation C Learances; R Ooftop I Nstallations - Daikin DX17VSS181AA Installation Instructions Manual

Table of Contents

Advertisement

P
i
ReCautions FoR
nstallation
• Check the strength and level of the installation ground
so that the unit will not cause any operating vibration or
noise after installed.
• Fix the unit securely by means of the foundation bolts.
(Prepare 4 sets of 3/8" or 7/16" foundation bolts, nuts and
washers; all separately available.)
• It is best to screw in the foundation bolts until their ends
are 1 inch from the foundation surface.
i
C
nstallation
leaRanCes
• Where a wall or other obstacle is in the path of the out-
door unit's intake or exhaust airfl ow, follow the installation
space requirements below.
• For any of the below installation patterns, the wall height
on the outlet side should be 47" or less.
Wall facing one side
More than 4"
Direction
of air
Side view
Walls facing two sides
More
than 4"
More
than 14"
More
than 4"
More than 2"
Walls facing three sides
More than 2"
This unit can be located at ground fl oor level or on fl at roofs.
More than 14"
47" or
less
More
than 14"
More than 2"
Top view
More than 4"
More than 14"
Top view
unit: inch
At ground fl oor level, the unit must be on a solid, level foun-
dation that will not shift or settle. To reduce the possibility
of sound transmission, the foundation slab should not be in
contact with or be an integral part of the building foundation.
Care should be taken to ensure the unit is installed away
from noise sensitive locations such as bedrooms, windows
and outdoor living areas. Ensure the foundation is suffi cient
to support the unit. A concrete slab raised above ground level
provides a suitable base.
R
i
ooFtoP
nstallations
If it is necessary to install this unit on a roof structure, ensure
the roof structure can support the weight and that proper
consideration is given to the weather-tight integrity of the roof.
Since the unit can vibrate during operation, sound vibration
transmission should be considered when installing the unit.
Vibration absorbing pads or springs can be installed between
the air conditioner unit legs or frame and the roof mounting
assembly to reduce noise vibration.
e
n
leCtrICAl
oIse
The unit should be well grounded so that potential effects of
electrical noise from the inverter to surrounding equipment
can be minimized.
When selecting an installation location, keep suffi cient dis-
tance from the air conditioner unit and wiring to radios, per-
sonal computers, stereos, fl uorescent lamp, etc., as shown
in the following fi gure.
To Indoor Unit and
Thermostat
Radio, TV
(In.)
Placement to Minimize Electronic Noise
3
Circuit
Breaker
High voltage
power cable