C Odes & R Egulations; F Eatures; P Recautions For S Electing A L Ocation - Daikin DX17VSS181AA Installation Instructions Manual

Table of Contents

Advertisement

C
& R
odes
egulations
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes
and/or prevailing local codes/regulations is the responsibility
of the installer. The manufacturer assumes no responsibility
for equipment installed in violation of any codes or regulations.
Rated performance is achieved after 72 hours of operation.
Rated performance is delivered at the specified airflow. See
outdoor unit specification sheet for split system models or
product specification sheet for packaged and light commercial
models. Specification sheets can be found at www.daikin-
comfort.com for Daikin products. Within the website, please
select the products menu and then select the submenu for
the type of product to be installed, such as air conditioners,
to access a list of product pages that each contain links to
that model's specification sheet.
The United States Environmental Protection Agency
(EPA) has issued various regulations regarding the in-
troduction and disposal of refrigerants. Failure to follow
these regulations may harm the environment and can
lead to the imposition of substantial fines.
Should you have any questions please contact our local EPA
office.
If replacing one of the component of the system, the system
must be manufacturer approved and Air Conditioning, Heating
and Refrigeration Institute (AHRI) matched.
NOTE: The installation of an inverter air conditioner with
unmatched system units will not allow for proper operation.
NOTICE
I
A/C
nverter
models CAn only be mAtChed wIth A CApeA
** A-
. d
Chpe
CoIl
AmAge resultIng from operAtIon wIth Any other
CombInAtIon Is not Covered by our wArrAntIes
Outdoor inverter units are approved for operation above 0°F
in cooling mode with no additional kit necessary.
Damage resulting from operation of the unit in a structure
that is not complete (either as part of new construction or
renovation) is not covered by our warranties.
F
eatuRes
This air conditioner is part of a system that uses inverter
technology to more efficiently remove heat and achieve the
target cooling setting. System may ONLY be installed using
a ComfortNet™ thermostat with model number CTK04AE or
newer as part of the digital communicating system. The Com-
fortNet system reduces the number of required thermostat
wires, provides additional setup features and enhanced active
diagnostics. Due to components using inverter technology, the
air conditioner will not function properly if used with a CTK03,
02 or 01 ComfortNet thermostat.
NOTICE
s
CtK04Ae
hould use
or newer
n
ot Approved for use wIth A
CtK04Ad
.
or older
**
.
.
CtK01, CtK02, CtK03,
P
ReCautions FoR
1. Choose a place solid enough to bear the weight and
vibration of the unit, where the operating sound will
not be amplified.
2. Choose a location where the hot air discharged
from the unit or the operating sound will not cause a
nuisance to the neighbours of the user.
3. Avoid places near a bedroom and the like, so that the
operating sound will cause no trouble.
4. There must be sufficient spaces for carrying the unit
into and out of the site.
5. There must be sufficient space for air passage and no
obstructions around the air inlet and the air outlet.
6. The site must be free from the possibility of flammable
gas leakage in a nearby place.
7. Do not install the air conditioner in the following
locations:
(a) Where a mineral oil mist or oil spray or vapor is produced,
for example, in a kitchen.
Plastic parts may deteriorate and fall off and thus may
result in water leakage.
(b) Where corrosive gas, such as sulfurous acid gas, is pro-
duced.
Corroding copper pipes or soldered parts may result in
refrigerant leakage.
(c) Near machinery emitting electromagnetic waves.
Electromagnetic waves may disturb the operation of the
control system and cause the unit to malfunction.
(d) Where flammable gas may leak, where there is carbon fi-
ber, or ignitable dust suspension in the air, or where vola-
tile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in a fire.
And
NOTE: Cannot be installed suspended from ceiling or stacked.
w
hen operAtIng the AIr CondItIoner In
A low outdoor AmbIent temperAture
be sure to follow the InstruCtIons
desCrIbed below
• t
o prevent exposure to wInd
the outdoor unIt wIth Its suCtIon
sIde fACIng the wAll
• n
ever InstAll the outdoor unIt At A
sIte where the suCtIon sIde mAy be
exposed dIreCtly to wInd
• t
o prevent exposure to wInd
reCommended to InstAll A bAffle
plAte on the AIr dIsChArge sIde of
the outdoor unIt
• I
n heAvy snowfAll AreAs
InstAllAtIon sIte where the snow
wIll not AffeCt the unIt
2
s
l
eleCting a
CAUTION
• Construct a large
,
canopy.
• Construct a pedestal.
.
,
InstAll
.
.
,
It Is
Install the unit high
enough off the ground
to prevent burying in
.
snow.
,
seleCt An
.
oCation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx17vss seriesDx17vss241aaDx17vss301aaDx17vss361aa

Table of Contents