AIR FOR COMBUSTION AND VENTILATION
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must provide
two permanent openings: one within 12" of the
ceiling and one within 12" of the floor on the
wall connecting the two spaces (see options
1 and 2, Figure 2). You can also remove door
into adjoining room (see option 3, Figure 2).
Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and
Ventilation for required size of ventilation
grills or ducts.
Ventilation
Grills Into
Adjoining
Or
Room,
Remove
Option 1
Door into
Adjoining
Room,
Option
3
Figure 2 - Ventilation Air from Inside Building
NOTICE: This appliance is intended
for supplemental heating. Use this
appliance along with your primary
heating system. Do not install this ap-
pliance as your primary heat source.
If you have a central heating system,
you may run system's circulating
blower while using appliance. This
will help circulate the heat throughout
the house. In the event of a power
outage, you can use this appliance
as your primary heat source.
WARNING: A qualified service
person must install appliance. Fol-
low all local codes.
NOTICE: State or local codes may only allow
operation of this appliance in a vented con-
figuration. Check your state or local codes.
8
12"
Ventilation Grills
Into Adjoining Room,
Option 2
12"

INSTALLATION

SuperiorFireplaces.us.com
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the floor. Connect these
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings
for inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Outlet
Air
Inlet
Air
Figure 3 - Ventilation Air from Outdoors
WARNING: Any outside air ducts
and/or ash dumps in the fireplace
shall be permanently closed at time
of appliance installation.
WARNING: Make sure the se-
lector switch is in the OFF position
before installing appliance.
WARNING: Seal any fresh air
vents or ash clean-out doors located
on floor or wall of fireplace. If not,
drafting may cause pilot outage
or sooting. Use a heat-resistant
sealant. Do not seal chimney flue
damper.
Ventilated
Outlet
Attic
Air
Ventilated
Inlet Air
Crawl Space
To Attic
To
Crawl
Space
126816-01E