See Pages 36-40 for a complete replacement parts
list. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your
IHP distributor or dealer. Parts will be shipped at
prevailing prices at time of order.
NEVER USE SUBSTITUTE MATERIALS. USE OF
NON-APPROVED PARTS CAN RESULT IN POOR
PERFORMANCE AND SAFETY HAZARDS.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• appliance will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TF18NR
• Rating (Variable): 21,000/30,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
TF2430NR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
To
Thermopile
126816-01E

REPLACEMENT PARTS

SPECIFICATIONS

*For purpose of input adjustment

WIRING DIAGRAM

To OFF Terminal
on Switch
To AUTO Terminal
on Switch
SuperiorFireplaces.us.com
When ordering repair parts, always give the follow-
ing information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any ques-
tions concerning the installation or application of
this appliance, please contact your dealer.

TECHNICAL SERVICE

You may have further questions about instal-
lation, operation, or troubleshooting. Please
contact your IHP dealer for any questions or
concerns. When contacting your dealer please
have your model and serial numbers of your
appliance ready. You can also visit our web site
at SuperiorFireplaces.us.com.
TF18PR
• Rating (Variable): 24,000/30,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
TF2430PR
• Rating (Variable): 28,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring
errors can cause improper
and dangerous operation.
Verify proper operation after
servicing.
33