Quick Start Guide
6.0
Mounting the transmitter above a liquid surface
A 2-in. thread is provided to mount the transmitter. The thread form is either
BSPT or NPT, and is clearly marked on the hexagon of the transmitter body.
To help with an installation, flange accessories and bracket kits are available
from Emerson. The accessory flanges supplied are manufactured from PVC and
are a full face design. Care must be taken when installing to raised face mating
flanges on the tank or vessel to prevent distortion of the PVC flange by
over-tightening the bolts (see
Refer to Rosemount 3101, 3102, and 3105
Emerson/Rosemount.com
6.1

Bracket mounting

The bracket kit contains a stainless steel angle bracket and PVC threaded disc
(Figure
6), which may be used to mount the transmitter on a support over the
liquid surface.

Installation instructions

1. Attach bracket to the disc using the three screws provided.
2. Attach the assembled bracket and disc to a rigid support over the liquid
surface.
The bracket may be bolted to a suitable cross member. Ensure the
transmitter is perpendicular to the surface to maximize the return echo size.
3. Use PTFE tape on the transmitter's screw thread.
4. Insert the transmitter into the disc.
5. Tighten to a torque of 1.5 ft-lb (2 N-m) using the transmitter's hexagon.
Do not use the transmitter housing to tighten.
Figure 6. Bracket Mounting
A
B
A. Stainless steel bracket
B. No. 4X 13 long self tap screws (x3), carbon steel (zinc plated)
C. PVC disc
10
"Installation instructions" on page
Product Data Sheet
for accessory ordering information.
C
September 2018
11).