Communications Reporting Codes - DSC 3G2060 Installation Manual

Internet/hspa alarm communicator
Table of Contents

Advertisement

Ethernet/Cellular Programming Options
[013] DLS Outgoing Port
Default (0BFA/3066)
The DLS Outgoing Port is used for outgoing session to DLS IV after an SMS request has been
sent to the Communicator. Use this Section to set the value of the local outgoing port. The value
must be changed if the Communicator is located behind a firewall and must be assigned a particu-
lar port number, as determined by your network administrator. In most cases, changing the default
value or configuring your firewall with this port is not required.
Valid range: 0000-FFFF.
NOTE: If Section [006] Toggle Option [7] is ON, DLS will use the Primary path for session. If
Section [006] Toggle Option [7] is OFF DLS will use the Ethernet path, if available.
[021] Account Code
Default (FFFFFF)
The account code is included when transmitting any events generated by the Communicator. (e.g.,
Panel Absent Trouble). It is recommended that the account code be the same as the control panel
account number. Valid range: 000001-FFFFFE. If 4 digit account codes are needed the 2 lowest
digits shall be programmed as FF (e.g., Account 1234 is programmed as:1234FF).
NOTE: Programming this Section with all 0 or F will cause a Module Configuration Trouble.
NOTE: This section shall sync with Panel Option [310] with Panel version 4.50 or higher.
[022] Communications Format
Default (04)
Program 03 for Contact ID (CID). Program 04 for SIA. The module can be configured to send
Events in SIA or CID format. The SIA communication format follows the level 2 specifications of
the SIA Digital Communication Standard - October 1997. This format will send the account code
along with its data transmission. The transmission will look similar to the following at the
receiver.
NOTE: This section shall sync with panels version 4.50 or higher.
Example:
Nri0 ET001 where: N = New Event; ri0 = Partition/Area identifier; ET = Panel Absent Trouble;
001 = Zone 001.

Communications Reporting Codes

Table 10: Communications Reporting Codes
Event
[023] Panel Absent Trouble
[024] Panel Absent Trouble Restore
[025] Radio Activation Restore
[026] Ethernet 1 Test Transmission
[027] Ethernet 2 Test Transmission
[028] Cellular 1 Test Transmission
[029] Cellular 2 Test Transmission
[030] FTC Restore
[023] Panel Absent Trouble
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with
the panel have been lost for more than 60 seconds.
[024] Panel Absent Trouble Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with
the control panel have resumed.
SIA
SIA
Reporting
Identifier
Code
ET
001
ER
001
RS
001
RP
001
RP
002
RP
003
RP
004
YK
001
17
3G Alarm Communicator Installation Manual
CID
CID
Event
Qualifier
Code
1
3
3
3
3
5
1
6
1
6
1
6
1
6
3
3
CID
CID
Reporting
User/
Code
Zone
55
001
55
001
52
001
A3
951
A3
952
A3
955
A3
956
54
001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl2603gTl260