Denon PMA-1600NE Owner's Manual page 46

Hide thumbs Also See for PMA-1600NE:
Table of Contents

Advertisement

Contents
Connections
o Power does not turn on / Power is turned off
Symptom
Power is not turned on.
0
Power automatically turns
0
off.
Power turns off and the
0
power indicator flashes in
red approx. every 0.5
0
seconds.
Power turns off and the
0
power indicator flashes in
red approx. every 0.25
seconds.
0
When the power is turned
0
on, the power indicator
flashes red approx. every
0.25 seconds.
Front panel
Rear panel
Playback
Check whether the power plug is correctly inserted into the power outlet.
The Auto Standby mode is set. The Auto Standby mode switches the unit to standby mode when the unit
is not operated for approximately 30 minutes. To disable the Auto Standby mode, press and hold the
AMP POWER X button for more than 5 seconds when the Auto Standby mode is enabled.
The protection circuit has been activated due to a rise in temperature within this unit. Turn the power off,
wait about an hour until this unit cools down sufficiently, and then turn the power on again.
Please re-install this unit in a place having good ventilation.
Check the speaker connections. The protection circuit may have been activated because speaker cable
core wires came in contact with each other or a core wire was disconnected from the connector and
came in contact with the rear panel of this unit. After unplugging the power cord, take corrective action
such as firmly re-twisting the core wire or taking care of the connector, and then reconnect the wire.
Turn down the volume and turn on the power again.
This unit's amplifier circuit has failed. Turn off the power and please contact the Denon service adviser.
Remote control
unit
Settings
Cause / Solution
46
Index
Tips
Appendix
Page
25
42
52
17
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents