HP 10500 Series Configuration Manual page 201

Hide thumbs Also See for 10500 Series:
Table of Contents

Advertisement

1
1
Influenced service according to following table on chassis 1 slot 0:
flash:/feature1-r0202.bin
feature1
Influenced service according to following table on chassis 1 slot 1:
flash:/feature1-r0202.bin
feature1
<Sysname> install activate feature flash:/feature1-r0202.bin chassis 1 slot 0 test
Verifying the file flash:/feature1-r0202.bin on chassis 1 slot 0...Done.
Upgrade summary according to following table:
flash:/feature1-r0202.bin
Running Version
Alpha 0201
Chassis
Slot
1
0
Influenced service according to following table on chassis 1 slot 0:
flash:/feature1-r0202.bin
feature1
The output shows that all the MPUs need a service upgrade and the feature module and related modules
might be rebooted during the upgrade.
# Activate the new feature image to upgrade the feature.
<Sysname> install activate feature flash:/feature1-r0202.bin chassis 2 slot 1
flash:/feature1-r0202.bin already exists on chassis 2 slot 1.
Overwrite it?[Y/N]:y
Copying file flash:/feature1-r0202.bin to
chassis2#slot1#flash:/feature1-r0202.bin......Done.
Verifying the file flash:/feature1-r0202.bin on chassis 2 slot 1...Done.
Upgrade summary according to following table:
flash:/feature1-r0202.bin
Running Version
Alpha 0201
Chassis
Slot
2
0
2
1
Upgrading software images to compatible versions. Continue? [Y/N]: y
This operation maybe take several minutes, please wait......................Done.
<Sysname> install activate feature flash:/feature1-r0202.bin chassis 2 slot 0
flash:/feature1-r0202.bin already exists on chassis 2 slot 0.
Overwrite it?[Y/N]:y
Copying file flash:/feature1-r0202.bin to
chassis2#slot0#flash:/feature1-r0202.bin......Done.
Verifying the file flash:/feature1-r0202.bin on chassis 2 slot 0...Done.
Service Upgrade
CFA
CFA
New Version
Alpha 0202
Upgrade Way
Service Upgrade
CFA
New Version
Alpha 0202
Upgrade Way
Service Upgrade
Service Upgrade