8.0 Operational problems -

troubleshooting

Poor draught
Check the length of the chimney and that it complies with
national laws and regulations. (See also «2.0 Technical
data» and «4.0 Installation» (Chimney and flue pipe)
Make sure that the minimum cross section on the
chimney is according to «2.0 Technical data»
Make sure that there is not anything preventing the
smoke gases from escaping: branches, trees, etc.
Upon suspicion of excessive/poor draught in the chimney,
seek professional help for measurement and adjustment
The fire extinguishes after a while
Make sure that the firewood is sufficiently dry
Find out whether there is negative pressure in the house,
close mechanical fans and open a window close to the
fireplace
Check that the air vents are open
Check that the flue outlet is not clogged by soot
Unusual amount of soot accumulates on
the glass
Some soot will always stick to the glass, but the quantity
depends on:
J
Moisture in the fuel
The local draught conditions
The air vents opening
Most of the soot will normally burn off when the air vents are
opened all the way, and a fire is burning briskly in the fireplace.