Detecting And Selecting The Available Channels Automatically (Urx-M1 Only); Setting The Attenuation Level Of The Audio Input (Utx-B1 Only) - Sony UWP-X5 Operating Instructions Manual

Wireless microphone package
Hide thumbs Also See for UWP-X5:
Table of Contents

Advertisement

the reception channel, the unit may not
operate normally. Wait a few seconds
before turning it on again.
Detecting and selecting the
available channels
automatically (URX-M1
only)
When multiple diversity tuner modules
(URX-M1) are installed into the MB-X6 to
perform simultaneous multiple-channel
operation, select the channel group on the
tuner module installed into the slot 1 of
the MB-X6, then all the tuner modules
installed into the MB-X6 can be set to
different channels within the selected
channel group.
1
Turn off all the microphones and
transmitters.
2
Select the channel group on the tuner
module installed into the slot 1 of the
MB-X6.
3
After confirming that the channel
group indication has stopped flashing
(about 10 seconds after you have
selected the channel group), keep
pressing the + button on the tuner
module installed into the slot 1 of the
MB-X6.
All the tuner modules installed into the
MB-X6 are set to the available
channels within the selected channel
group.
After the automatic detection and
selection of available channels finish,
you can change the group and channel
on each tuner module manually.
Notes
• Do the automatic detection and selection
of available channels with the channel
group other than channel group 00.
• When there are unavailable channels due
to extraneous radio wave and the channel
could not be selected on some tuner
modules, "NO CH" appears on the
display of those tuner modules. If this
happens, select the channel group with no
interference from extraneous radio wave,
and repeat the procedure above.
Setting the attenuation
level of the audio input
(UTX-B1 only)
The attenuation level can be set during
signal transmission.
1
Do the following while there is
no signal transmission.
Turn on the transmitter while pressing
down the SET button, and press the
SET button repeatedly until the
attenuation level indication appears in
the display section.
Do the following while there is
signal transmission.
Press the SET button repeatedly until
the attenuation level indication appears
in the display section.
2
Press the + or – button to select the
attenuation level.
The selectable range is from 0 dB to 21
dB in steps of 3 dB (the factory setting
is 0 dB).
Settings
17

Advertisement

Table of Contents
loading

Table of Contents