Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
To install the replacement battery, complete the following steps:
1. Follow any special handling and installation instructions that come with the
replacement battery.
2. Insert the replacement battery:
a. Position the battery so that the positive (+) symbol is facing away from you.
b. Use one finger to press the top of the battery clip away from the battery.
c. Press the battery into the socket until it clicks into place. Make sure that the
battery clip holds the battery securely.
3. Install the left-side cover and bezel (see "Removing the left-side cover and
bezel" on page 57).
4. Connect the cables and power cords (see "Completing the installation" in the
Installation Guide or User's Guide for cabling instructions).
Note: You must wait approximately 20 seconds after you connect the power
cord of the server to an electrical outlet before the power-control button
becomes active.
5. Turn on all attached devices and the server.
6. Start the Configuration/Setup Utility program and reset the configuration:
v Set the system date and time.
v Set the power-on password.
v Reconfigure the server.
See "Using the Configuration/Setup Utility program" on page 14 for details.