v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3500 Type 7977," on page 41 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
001-198-000
Test aborted.
001-250-001
Failed system board ECC
001-292-000
Core system: failed/CMOS checksum failed. Load the BIOS default settings by using the
005-xxx-000
Failed video test.
011-xxx-000
Failed COM1 serial port test.
015-xxx-001
Failed USB test.
015-xxx-198
Remote Supervisor Adapter II SlimLine
installed or USB device connected during
USB test.
035-285-001
Adapter Communication Error
035-286-001
Adapter CPU Test Error
035-287-001
Adapter Local RAM Test Error
035-288-001
Adapter NVSRAM Test Error
This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU or FRU. Take the action that is indicated in the Action
column, but do not replace a CRU or a FRU. See the description of
Warning in "Diagnostic text messages" on page 140 for more information.
Action
1. Check the diagnostic logs for messages that
indicate the cause of the error, and take the
indicated action.
2. From the diagnostic programs, run Quick Memory
Test All Banks; then, if an error is detected, take
the indicated action.
3. Reinstall and, if necessary, update the BIOS code
on the server; then, run the test again (see
"Updating the firmware" on page 13).
(Trained service technician only) Replace system
board.
Configuration/Setup Utility program, and run the test
again (see "Using the Configuration/Setup Utility
program" on page 14).
1. Reseat the video adapter, if one is installed.
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
1. If a Remote Supervisor Adapter II SlimLine is
installed as an option, remove it and run the test
again.
2. Remove all USB devices and run the test again.
3. (Trained service technician only) Replace the
system board.
1. Update the RAID controller firmware.
2. Reseat, and if necessary replace the controller.
1. Update the RAID controller firmware.
2. Reseat, and if necessary replace the controller.
1. Update the RAID controller firmware.
2. Reseat, and if necessary replace the controller.
1. Update the RAID controller firmware.
2. Reseat, and if necessary replace the controller.
141
Chapter 5. Diagnostics