Installation

4.6 Wall mounting

4.6
Wall mounting
Wall mounting
Note
The wall mounting must be capable of supporting at least four times the weight of the X-200,
see section Technical specifications (Page 85).
When mounting on a wall, use mounting fittings suitable for the type of wall. To secure the
device in concrete, you could, for example use the following material:
● 4 wall plugs, 6 mm in diameter and 30 mm long
● 4 screws 3.5 mm in diameter and 40 mm long
Follow the steps below to install the X-200 on a wall:
1. Prepare the drill holes for wall mounting.
You will find the precise dimensions in the Appendix Dimension drawings (Page 97).
2. Connect the electrical cable connecting cables.
3. Fit the connectors for the signaling contact.
4. Insert the terminal blocks or M12 cable connectors into the sockets on the IE Switch X-
200.
5. Screw the device to the wall.