Siemens RUGGEDCOM RS416P Installation Manual page 29

Hide thumbs Also See for RUGGEDCOM RS416P:
Table of Contents

Advertisement

RUGGEDCOM RS416P
Installation Guide
Serial DB9 Port with IRIG-B Support
Figure 26: Serial DB9 Port Pin Configuration
d
In RS232 DTE mode, ports transmit to DTE devices on pin 2 and receive from DTE on pin 3.
NOTE
Pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high impedance state. A
DTE that asserts RTS will see CTS asserted. However, the device will not perform hardware flow
control.
Serial RJ45 Port
8
Figure 27: Serial RJ45 Port Pin Configuration
e
The DSR, DCD and DTR pins are connected together internally.
f
In RS232 mode, the RJ45 ports conform to EIA-561 DTE, which transmit on TXD and receive on RXD.
NOTE
Pins 1, 2 and 3 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high
impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform
hardware flow control.
Serial Ports
5
1
9
6
1
Pin
RS232 DTE
1
d
2
RX
d
3
TX
4
5
Common (Isolated) Ground
6
Common (Isolated) Ground
7
RTS
8
CTS
9
Common (Isolated) Ground
Shield
Chassis Ground
Pin
RS232 Mode
e
1
DSR
e
2
DCD
e
3
DTR
4
Common (Isolated) Ground
f
5
RXD
f
6
TXD
7
CTS
8
RTS
Shield
Chapter 3
Communication Ports
Mode
RS485
RS422
RX-
TX/RX+
TX+
RX+
IRIG-B+
TX/RX-
TX-
RS485 Mode
RS422 Mode
RX-
RX+
TX/RX+
TX+
TX/RX-
TX-
Chassis Ground
23

Advertisement

Table of Contents
loading

Table of Contents