Siemens RUGGEDCOM RS416P Installation Manual page 28

Hide thumbs Also See for RUGGEDCOM RS416P:
Table of Contents

Advertisement

Chapter 3
Communication Ports
Fiber Serial Port
Figure 24: ST Port
1. Tx Connector
2. Rx Connector
Serial DB9 Port
Figure 25: Serial DB9 Port Pin Configuration
a
The DSR, DCD and DTR pins are connected together internally.
b
In RS232 DCE mode, ports transmit to DTE devices on pin 2 and receive from DTE on pin 3.
c
RI is not connected.
NOTE
Pins 1, 4 and 6 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high
impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform
hardware flow control.
22
1
5
1
9
6
2
Pin
RS232 DCE
a
1
DCD
b
2
TX
b
3
RX
a
4
DTR
5
Common (Isolated) Ground
a
6
DSR
7
RTS
8
CTS
c
9
RI
Shield
Chassis Ground
RUGGEDCOM RS416P
Installation Guide
Mode
RS485
RS422
TX/RX+
TX+
RX+
RX-
TX/RX-
TX-
Serial Ports

Advertisement

Table of Contents
loading

Table of Contents