2.2 - ACCESSORIES SUPPLIED WITH THE UNIT
ty
Accessory
Q
1 - Support plate
1
2 - Instructions
2
3 - Dowels
6
2.3 - WEIGHT
Net weight (kg)
MCW1-2
8
MCW3-4
12
A
270
MCW1-2
285
MCW3-4

3 - INSTALLATION OF THE UNIT

3.1 - CHOOSING THE LOCATION
• Select the location for the unit on the basis of the following
criteria:
- The device is intended for installation in sheltered premises
(IP 20). Do not install in very damp places or exposed to
projHigh speedections of water.
- Do not place above electrical sockets.
- The air intake and blowing grilles must be free from any
obstacle so that blowing can occur correctly in the whole
room.
- The wall on which the air handler will be fixed must be
sufficiently thick for there not to be any resonance and so as
not to produce any noise.
- Provide for the pipes and electric cables.
- It is essential to leave the clear space around the unit (see
drawing).
3.2 - INSTALLATION OF THE SUPPORT PLATE
• Remove
the
mounting
screw from the support
plate.
• Press at the points indicated
by a triangle to unhook the
plate's two lugs.
• The unit may be connected
at 5 different points:
- on either the right or left-
hand side,
- at either the right or left-
hand rear,
- on the lower right-hand side.
Use
Wall support for the unit.
Installation instructions.
Operating instructions.
For fixing the support plate.
Packed weight (kg)
10
14
B
C
805
177
995
206
Accessory
Q
ty
4 - Screws
6
5 - Seals
2
2.4 - DIMENSIONS
C
- Do not install units with electric heating near combustible
materials or surfaces.
• Use the support plate as a jig to locate the rear outlets. Place
the plate level against the wall and mark the hole to be made.
For an outlet at the left-hand rear of the unit, use the plate's
most outside mark.
The Ø 65 mm hole in the upper right-hand corner of the
plate can also
Ø 65 mm (MCW1-2)
be used thus
allowing
the
tubes to exit
straight into the
wall.
• Mount the plate
NO
on
the
wall
using
the
s u p p l i e d
screws
and
dowels.
To avoid vibrations, ensure that the panel is mounted securely
against the wall.
Utse
For fixing the support plate
with the dowels.
Connection of flexible tubes
on the installation
(Ø 1/2" - 15 x 21)
B
111
YES
NO
F
GB
I
E
D
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mcw-be seriesMcw 1 b 5bMcw 2 b 5bMcw 1 be 5bMcw 3 b 5bMcw 4 b 5b

Table of Contents