Note: Text displayed in Bold-Italics designate standard offering.
Category
Product Category
Model Type
Design Series
Unit Size
Controls
Voltage
Secondary Drain Pan
Refrigerant
Motorized 2-way Isolation Valve
Chassis Construction Type
Note:
A compressor sound blanket is not recommended
for units with a rotary compressor
(Unit sizes 009-021)
Coaxial Heat Exchanger
Construction
Discharge Air
Power Connection
IM 986-11 • Vertical Stack WSHP
Code Item
Code Option
1
1
2
2, 3, 4
3
5
4
6, 7, 8
5
9
6
10
7
11, 12
8
13
9
14
10
15
16
11
18
13
20
21
22
14
23
Code Designation & Description (Bold-Italic = Standard)
W
= Water Source Heat Pump
VHC = Vertical Stacked Heat Pump Chassis
VHF = Vertical Stacked Heat Pump Cabinet
VHW = Vertical Stacked Geothermal Chassis only
3
= 3rd Design
4
= 4th Design (Sizes 015 only)
009
= 9,000 Btuh Nominal Cooling
012
= 12,000 Btuh Nominal Cooling
015
= 15,000 Btuh Nominal Cooling
018
= 18,000 Btuh Nominal Cooling
021
= 21,000 Btuh Nominal Cooling
024
= 24,000 Btuh Nominal Cooling
030
= 30,000 Btuh Nominal Cooling
036
= 36,000 Btuh Nominal Cooling
B
= MicroTech III Unitary Controller - Standalone
C
= Microtech III Unitary Controller w/L
D
= Microtech III Unitary Controller w/BACnet Comm Module
F
= Microtech III Unitary Controller w/BACnet Comm Module - WSHP System
A
= 115/60/1
E
= 208-230/60/1
J
= 265-277/60/1
GL
= Standard Galvanized
SS
= Stainless Steel - IAQ Option
YY
= None
A
= R410A
C
= 2-Way Motorized 1/2" Iso-Valve, General Close-Off Pressure N.C.
(Normally Closed)
V
= 2-Way Motorized 1/2" Iso-Valve, General Close-Off Pressure N.O.
(Normally Open)
H
= 2-Way Motorized 1/2" Iso-Valve, High Close-Off Pressure N.C. (Normally Closed)
D
= 2-Way Motorized 3/4" Iso-Valve, General Close-Off Pressure N.C. (Normally Closed)
K
= 2-Way Motorized 3/4" Iso-Valve, General Close-Off Pressure N.O. (Normally Open)
J
= 2-Way Motorized 3/4" Iso-Valve, High Close-Off Pressure N.C. (Normally Closed)
E
= 3-Way Motorized 1/2" Iso-Valve, General Close-Off Pressure N.C. (Normally Closed)
G
= 3-Way Motorized 1/2" Iso-Valve, High Close-Off Pressure N.C. (Normally Closed)
M
= 3-Way Motorized 3/4" Iso-Valve, General Close-Off Pressure N.C. (Normally Closed)
P
= 3-Way Motorized 3/4" Iso-Valve, High Close-Off Pressure N.C. (Normally Closed)
B
= Auto-Reg-PT
Y
= None
A
= 1/2" Fiberglass Skin Faced
E
= 3/8" Closed Cell Foam
F
= 1/2" Fiberglass - Foil Faced
Y
= None
M
= Mass Plate & Comp Blanket (Unit Sizes 024-036 Only)
S
= Mass Plate Only
C
= Copper Inner Tube - Steel Outer Shell
S
= Cupronickel Inner Tube - Steel Outer Shell
B
= Primary Supply - Back
F
= Primary Supply - Front
L
= Primary Supply - Left
R
= Primary Supply - Right
T
= Primary Supply - Top
Y
= None
B
= Secondary Supply - Back
F
= Secondary Supply - Front
L
= Secondary Supply - Left
R
= Secondary Supply - Right
T
= Secondary Supply - Top
Y
= None
T
= Tertiary - Top
F
= Fused Disconnect with Wire Harness
N
= Non-Fused Disconnect with Wire Harness
H
= HACR Breaker
4
M
n
odel
oMenClature