13

Parameter settings

.48
13

Selecting the function group and altering the parameter

.48.01
Switch on the machine.
When the machine is switched on, it is automatically active in the sewing mode.
Select the input mode (LED in the key is on).
Using the left +/- keys select the desired function group.
With the factory setting of the machine, only free access to function group "100" is
possible, the other function groups are protected against unauthorized access by a code.
Confirm the selection of the desired function group with the "enter" function by pressing
"+" on the right +/- key.
Select the desired parameter by using the left +/- keys, and change to the desired value
with the right +/- keys.
The altered value is taken over by selecting the next parameter.
or
By calling up the sewing mode the altered value is taken over and the machine changes
to the sewing mode (LED in the key goes off).
No
1 0 0
No
VA L
1 0 2
1
Adjustment