13
Parameter settings
.48
13
Selecting the function group and altering the parameter
.48.01
Switch on the machine.
●
When the machine is switched on, it is automatically active in the sewing mode.
Select the input mode (LED in the key is on).
●
Using the left +/- keys select the desired function group.
●
With the factory setting of the machine, only free access to function group "100" is
possible, the other function groups are protected against unauthorized access by a code.
Confirm the selection of the desired function group with the "enter" function by pressing
●
"+" on the right +/- key.
Select the desired parameter by using the left +/- keys, and change to the desired value
●
with the right +/- keys.
The altered value is taken over by selecting the next parameter.
●
or
By calling up the sewing mode the altered value is taken over and the machine changes
●
to the sewing mode (LED in the key goes off).
No
1 0 0
No
VA L
1 0 2
1
Adjustment
107