Synchronizing Transmitters With Receivers; Synchronizing A Transmitter With The Receiver - Individual Operation - Sennheiser evolution wireless series EM 100 Instruction Manual

Sennheiser microphone brochure
Table of Contents

Advertisement

Synchronizing transmitters with receivers

42
Synchronizing transmitters with
receivers
When synchronizing a transmitter with a receiver, please observe the
following:
Only use a transmitter and a receiver from the same frequency
range (see the type plate on the transmitter and the receiver).
Make sure that the desired frequencies are listed in the enclosed
frequency information sheet.
Make sure that the desired frequencies are approved and legal
in your country and, if necessary, apply for an operating license.
Synchronizing a transmitter with the receiver –
individual operation
Upon delivery, transmitter and receiver are synchronized with each other.
If, however, you cannot establish a transmission link between transmitter
and receiver, you have to synchronize the channels of the devices.
With the receiver, perform a frequency preset scan to scan the
frequency banks for unused channels
Then "Sync" appears on the display panel of the receiver.
PEAK
Easy Setup
40
0
-10
25
B.Ch:
20.12
-20
10
-30
Sync
533.875 MHz
RF
AF
Synchronize a transmitter with the receiver via the infra-red interface
(see page 20).
This establishes a transmission link between the transmitter and the
receiver.
Alternatively, you can set the channel on the transmitter manually:
Make sure that you set the transmitter to the same frequency bank and
the same channel as the receiver (see the instruction manual of the
transmitter).
("Scan New
List", see page 34).