(Fc_2) - Briggs & Stratton 040213 Service And Troubleshooting Manual

15000 watt home generator system
Hide thumbs Also See for 040213:
Table of Contents

Advertisement

2
Test 1
Measure for
short-to-ground
on Wire #85.
Shorted?
No
Test 2
Measure
engine oil
pressure.
Within
Spec?
No
Repair/replace
engine as
required.
Fig. 15 - (FC_2) Low Oil Pressure Troubleshooting Flowchart
Page 26
Service & Troubleshooting Guide - Home Generator System - Models 040213 and 040234 (15kW)

(FC_2)

Low Oil Pressure Test
Repair/replace
Yes
Wire #85
Reset FC
Start Unit
Test 3
Check
Yes
oil pressure
switch.
Section 2 - Troubleshooting Information
END
No
Fault
Detected?
Yes
Replace oil
No
pressure switch.
Switch
OK?
Yes
Replace CMA
Reset FC
Start Unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

040234

Table of Contents