Service & Troubleshooting Guide - Home Generator System - Models 040213 and 040234 (15kW)
Section 1 - General Information

SYSTEM CONTROLS

15 Amp Fuse
- Protects the Home Standby Generator
System DC control circuits. If the fuse has melted open or
was removed, the engine cannot crank or start. Replace
the fuse using only an identical ATO 15A fuse.
Circuit Breaker
- Protects the system from over
current conditions and must be in the ON position to
supply power to the automatic transfer switch.
Digital Display
- Used as an hour meter and to show
various fault indications.
INDICATIONS" on page 20.)
MANUAL OVER-RIDE
manually. Push and hold to start and shut unit down.
(SYSTEM switch must be in AUTO for MANUAL-
OVERIDE to operate.
(See "FAULT CODE
- Used to start the engine
Service Tool
- For use by qualified service technicians
only.
SET EXERCISE
- Used to set the exercise cycle start
time and day of the week. Exercise cycle only occurs in
the
mode.
AUTO
SYSTEM
- This two position switch operates as follows:
• AUTO
position is the normal operating mode. If a
utility power outage is sensed, the generator will start
automatically. When utility power is restored, the
generator will shut down and is ready for the next
utility power outage.
• OFF
position turn off a running generator, prevents
generator from starting and resets any fault
indications.