Download Print this page

SECO-LARM Enforcer E-941DA-1K2P Installation Manual page 3

Electromagnetic locks

Advertisement

ELECTROMAGNETIC LOCK Installation Manual
FIG.
1
Standard
Mounting
(Z/L brackets are not available for E-941SA-300.)
FIG.
Steel and
Rubber washers
2
Sexnut tube
(as needed)
Armature
1 2 3 4 5
Armature
Sexnut
1 2 3 4 5
Screw
bolt
Drill a 8mm
This side drill
hole thru door
16mm only
HOLLOW METAL DOOR
Drill an 8mm hole thru door. From sexnut
bolt side only, enlarge the 8mm hole to
16mm.
(E-941SA-600 &
FIG. 3
Power Cable
E-941SA-1200 only)
To Magnet
E-941SA-600
Control
Device
Power
+
Supply
-
Power Cable
Voltage Selection
To Magnet
12VDC
Magnet set for 12VDC
operation as supplied
from factory.
24VDC
Position a jumper over the
two middle pins for 24VDC
operation.
Filler
Plate*
* Note: may require more
"L" Bracket
than one filler plate.
Steel and
Rubber
washers
(as
needed)
1 2 3 4 5 6 7 8
Sexnut
1 2 3 4 5 6 7 8
bolt
Armature
Screw
Armature
Drill 12.7mm
Drill a 8mm
(1/2")
hole thru door
SOLID CORE DOOR
Drill an 8mm hole thru door. From sexnut
bolt side of door, drill 12.7mm (1/2") hole,
25mm (1") in depth.
-
+
ENFORCER
ENFORCER
Control
Device
INPUT
POWER
+
Important note:
-
Check jumper settings before connecting the
lock to the 24VDC input power. Damage to the
lock may result from incorrect jumper settings.
For Inswing Doors
"Z"
Bracket
Steel and
Rubber washers
(as needed)
1 2 3 4 5
1 2 3 4 5
Armature Screw
Armature
Tap M8 x 1.25 Thread
REINFORCED DOOR
Drill a 6.8mm dia. hole and tap for
M8 x 1.25 thread.
Voltage Selection
12VDC
Magnet set for 12VDC
operation as supplied
from factory.
24VDC
Position a jumper over the
two middle pins for 24VDC
operation.
E-941SA-1200
Power
+
Supply
-
Page 3

Advertisement

loading

This manual is also suitable for:

Enforcer e-941sa-1200Enforcer e-941sa-1k2pdEnforcer e-941sa-300Enforcer e-941sa-600