Smelly Water; Air In Hot Water Faucets; High Temperature Shut Offsystem; Not Enough Hot Water - Kenmore POWER MISER 153.335803 Owner's Manual

Power vent gas water heater
Table of Contents

Advertisement

Troubleshooting
Guide (cont'd)
Operational
Conditions
SMELLY
WATER
In each glasslined
water heater
there
is installed
at least one
anode rod (see parts
section)
for corrosion
protection
of the
tank. Certain water conditions
will cause a reaction between this
rod and the water. The most common
complaint
associated with
the anode rod is one of a "rotten egg smell". This odor is derived
from hydrogen sulfide gas dissolved in the water. The smell is
the result of four factors which must all be present for the odor
to develop:
a. a concentration of sulfare in the supply water.
b. little or no dissolved oxygen in the water.
c. a sulfate reducing bacteria within the water heater. (This
harmless bacteria is non-toxic to humans.)
d. an excess of active hydrogen in the tank. This is caused by
the corrosion protective action of the anode.
Smelly water may be eliminated
or reduced in some water heater
models by replacing the anode(s)
with one of less active material,
and then chlorinating
the water heater
tank and all hot water
lines. Contact
Sears Service for further information
concerning
an Anode
Replacement
Kit #9001453
and this Chlorination
Treatment.
If the smelly water persists after the anode replacement
and chlo-
rination
treatment,
we can only suggest that continuous
chlori-
nation
and filtering conditioning
equipment
be considered
to
eliminate
the water problem.
Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.
"AIR"
IN HOT
WATER
FAUCETS
AWARNING
HYDROGEN
GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely
flammable and explosive. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet
be opened fur several minutes at the kitchen sink before any
electrical applianceswhich are connected to the hot water sys-
I tern are used (such as a dishwasher or washing machine), If
hydrogen gas is present, there will probably be an unusual
sound similar to air escapingthrough the pipe as the hot water
faucet is opened. There must be no smoking or open flame
near the faucet at the time it is open.
HIGH
TEMPERATURE
SHUT
OFF
SYSTEM
This water heater is equipped
with an automatic
gas shut off sys-
tem. The high temperature
shut off is built into the gas control
valve. This system shuts off the gas supply to the water heater
burners
when
high water temperatures
are present.
It is non-
resettable. If the high temperature
shut off activates, the gas con-
trol valve must be replaced. If this were to occur, turn "OFF"
the
entire gas supply to the water heater. Contact
the Sears Service
Center.
&WARNING
Shouldoverheatingoccur or the gassupplyfail to shut off,
urn ' OFF" the manual gascontro valveto the app ante.
NOT
ENOUGH
OR NO
HOT
WATER
i
heck the manual gas shut offvalve to be sure it is open.
Check the pilot flame. It may have gone out, All models have
an opening behind the outer door for viewing the pilot.
If the piiot is not lit, follow the "Lighting" instructions
in this
manual
or located above the gas control valve on the water
heater to relight the pilot. If the water was extremdy hot and is
now cold, the high limit safety temperature shut off may have
put out the burner and pilot. If the high temperature
shut off
activates, the gas controlvalve
must be replaced. Contact
the
Sears Service Center.
The gas control knob must be turned to the "ON" position.
:" The temperature
adjustment dial may be set too low. See the
Temperature
Regulation" section.
The gas company can check the gas input to see if it is correct.
An underfired water heater will not beat water as quicldy.
Look for leaking or open hot water faucets. Make sure all are
dosed.
• The cold water inlet temperature
may be colder during the win-
ter months. It will take longer to heat the water and seem like
less hot water.
• If you cannot find what is wrong, call the Sears Service Center.
WATER
IS TOO
HOT
1. The temperature
adjustment
dial may be set too high. See the
"Temperature Adjustment"
section.
NOTE: A period of time is necessary after an adjustment has
been made for the water temperature
to reach the new tem-
perature setting.
2. If lower temperature
settings will not lower the water tempera-
ture, call the Sears Service Center.
&WARNING
Due to the nature of the typical gas water heater, the
water temperature in certain situations may he hotter
than the thermostat setting.
Short, frequent draws of hot water - especiallywith very
cold incoming water - can shockthe thermostat into brief
operation resulting in hotter and hotter layers of water
closerto the top of the tank.
Changes in hot water usagepatterns or raising the tem-
perature differential between the cut-on of the thermo-
stat and the cold water temperature will usuallyeliminate
the problem.