Kenmore POWER MISER 153.335803 Owner's Manual page 16

Power vent gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Venting (cont'd)
AWARNING
Be sure vent pipe is p,_porly connected to prevent escape of
dangerousflue gaseswhich could causedeadly asphyxiation,
VENTING
SYSTEM
EXAMPLE
INSTALLATIONS
FOR ALL MODELS
The vent piping cannot under any circumstances be run down-
hill.
AWARNING
Chemical vapor corrosion of the Rue and vent system may
occur if air for combustion contains certain chemical vapors,
Spray can propellants, cleaning solvents, refrigerator
and air
conditioner refrigerants,
swimming pool chemicals, calcium
and sodium chloride, waxes, bleach, and process chemicals are
typical compoundswhich are potentially corrosive.
3" PVC SCHEDULE
40 VENT PIPING
Supplied
in the carton with the water heater
are:
1. A 3" PVC Schedule
40-45 ° vent cap with wire screen.
2. A 3" PVC Schedule
40-90 ° street ell; used to connect
the
vent pipe to the water heater when
the vent pipe is to be
turned
horizontally
directly off the blower.
3. A 5' section
of 3" PVC
Schedule
40 pipe (more
may be
required and must be supplied
locally).
3"opvc S chedule 40
90 Elbow
Vent Cap with
Screen
1
1. The
water
heater
requires
its own
(separate)
venting
system.
2. 3" PVC, ABS or CPVC Schedule 40 piping and fittings are
acceptable materials for the vent system on all 40 gallon
models and 50 gallon 40,000 BTU/HR models.
3. It cannot
be connected
to existing
vent
piping
or
chimney.
4. It must terminate horizontally to the outdoors.
The vent piping can be installed as follows:
1. No more than 3 elbows can be used.
Max. 3
MIN. RISE ¼"
PER FOOT
TOTAL VERTICAL AND
HORIZONTAL RUNS
CANNOT EXCEED 35'
MAX_3
MIN. RISE ¼"
PER FOOT
MAX. 20'
MIN. RISE ¼"
PER FOOT
TOTAL VERTICAL AND
HORIZONTAL RUNS
CANNOT EXCEED 35'
16