Uperatmg Instructions - Kenmore POWER MISER 153.335803 Owner's Manual

Power vent gas water heater
Table of Contents

Advertisement

Operating
Instructions
-
This water heater is equipped with an electrically operated vent-
ing system and a standing pilot. For the burner to come on, the
water heater thermostat must call for heat. Then the system will
begin sequencing,
each section proving itself before gas is
allowed to flow to the burner.
BLOWER MOTOR
BEFORE
THE
WATER
HEATER
WILL
OPERATE:
1. The control system must be connected to a 110/120 volt
power supply. The control system has an overall rating of 2
amps. The water heater must be securely and adequately
grounded in accordance with local codes and with the latest
edition of the Nationa! Electrical Code ANSI/NFPA 70.
2. The ON/OFF
toggle switch, located on the control box
above the thermostat must be in the "ON" position for the
electrical control system to operate allowing the gas portion
to operate (ignite burner).
3. The pilot must be lit. See Lighting
instructions
on page 22
of this manual
or located adjacent to the thermostat
on the
water heater.
4. The
gas control
knob located
on the thermostat
must
be
turned to the "ON" position for the gas to be able to flow.
5. The venting
manual reset switch must be in the dosed posi-
tion. See
Venting
Manual Reset Switch
in the
For Your
Information
Section".
6. There is a non-resettable
hi-limit
switch in the thermostat,
which must be good (dosed)
for the thermostat
to be o_er-
ated. See 'High
Temperature
Shut Off System
in the
For
Your Information
Section".
OPERATION
When
the thermostat
calls for heat, gas in allowed to flow to a
(Normally
open) pressure switch closing it. An electrical circuit
is then made to the blower, turning
it on. The indicator
light
located on the control
box will come on. When the blower has
achieved sufficient venting, the airpressure switch will dose and
the indicator
light will go off. A 24volt
circuit will be complet-
ed through
the venting
manual
reset switch and on to the 24
volt gas valve located just below the thermostat.
The 24 volt gas
valve will open allowing gas to flow to the burner. The standing
pilot will establish a main burner flame.
VENTING
RESET SVVITCH
DRAFT HOOD
AIR PRESSURE
ON/OFF SWITCH
, SWITCH
24V/120V
TRANSF_
GAS CONTROL
KNOB,
GAS PRESSURE
SWITCH
BURNER
GAS THERMOSTAT
THERMOCOUPLE