Installation
Instructions
(cont'd)
USE WITHOUT
POWER
CORD
(cont'd)
3. A standard
½" conduit
opening
has been made in the water
heater junction
box for the conduit
connection.
4. Use wire nuts and connect
the power supply wiring
to the
wires "ns'de the water heaters junction
box.
5. The water
heater
must
be electrically
_grounded"
by the
installer.
A green ground
screw has been provided
on the
water heater's
junction
box. Connect
ground
wire to this
location.
For complete
grounding
details and all allowable
exceptions,
refer
to the latest
edition
of the National
Electrical Code.
6. Replace
the
wiring
junction
cover
using
the
screw
provided.
WIRING
DIAGRAM
SgflT_4
S_T_H
Venting
_WARNING
I
To insureproperventingof this gas-Ered water heater,the cot- I
rect vent pipe diameter must be utilized. Any additions of I
other gas appliances on vent with this water heater will
adversely affectthe operationofthe water heater.
The combustion
and ventilation
air flow must not be obstructed.
•,WARNING
,,
I
The vent pipe from the water heater must be 3 diameter I
PVC schedule 40 pipe and must slope upward I/4 inch per
near foot.
All vent gases must be completely
vented to the outdoors of the
structure (dwelling).
a_WARNING
I
The water heater with draft hood installed must be properly I
vented to a chimney which terminates
outdoors. Never oper-
_e the water heater unlessit isvented to the outdoors and has
adequate air supply to avoid risks of improper operation explo-
sion
or asphyxiation.
&WARNING
I
Obstructed or deteriorated vent systems may present a serious
health risk or asphyxiation.
Min. rise I/4"
per foot
15
A, WARNING
Failureto haverequiredclearances b etweenwater heater and
combustible materialwillresult in a fire hazard.