Rinnai RHFE-556FA Owner's Operation And Installation Manual page 61

Energysaver gas direct vent wall furnace
Hide thumbs Also See for RHFE-556FA:
Table of Contents

Advertisement

)
1. How to connect exhaust pipes
r
~/
Exhaust pipe
/
Exhaust pipe
Air intake hose
To connect the exhaust pipes, fit the male end into the female end and clamp with pipe stopper Ato prevent
slipping. The exhaust pipe can be telescoped to the required length; do not cut it.
Female end
Male end
Connect bent pipe
=:=:ID~
~d'
Pipe stopper A
2. How to connect air intake hose
Air intake hose
' "
Hose joint
, "
H'
,'.'1
. .
a;i;'
,M
flU
lh'~!
0' 1 ' 1 8
4-
~_:wiJWjjjiUimCi
Screw in counterclockwise
Main unit air intake hose
Screw hose joint half of its length onto the air intake hose, then screw another air intake hose into the joint.
The hose can be cut to the required length.
IMPORTANT: The PVC air line is longer than the exhaust line and may need to be cut to size. Be sure,
however, to thoroughly deburr all rough edges.
3. Affixing the air intake hose and exhaust pipe
4. How to use the bent pipe
. Set the air intake hose and exhaust pipe into the pipe
clamps, screw the clamp onto the wall fixture, and affix
to the wall with screw B.
. The air intake hose and exhaust pipe can also be
screwed onto the wall using the pipe clamp and
the nut.
With the exhaust pipes inserted into the ends, bend
the bent pipe to the angle reguired for installation.
This part is mainly used for curves and for connection
to vent terminal.
-59-