NOTE: Both the POOL and SPA setpoints will revert back to
65°F (18°C) and the POOL and SPA maximum temperature
settings will be 104°F (40°C). These setpoints will need to
be readjusted to desired settings.
NOTE: The LCD temperature display may not agree with
the temperature reading of your pool or spa thermometer.
The heater reads the water temperature at the inlet. Due
to the circulation characteristics of any pool or spa, the
water temperature at the inlet to the heater may differ
from that observed at a given location in the pool or spa.

5.4. Status and Diagnostics

The P-156 has a digital thermostat that is programmed
to display a variety of status and diagnostic messages,
depending on the operating conditions.
The following heat status messages are displayed in Pool,
Spa, and Remote modes when there are no active fault
conditions.
Display
Heating
Call for heat established, flame present.
Spark
Spark operating.
No Demand
Heat demand is satisfied.
Table K.
Heat Status Messages - No Active Faults
The following conditions are displayed in Pool, Spa and
Remote modes.
Display
Thermistor temperatures disagree by
Sensor Failure
more than 2°F (1°C)
Thermistor sensor failed open. Below
Sensor Open
-20°F (-29°C).
Thermistor sensor failed short. Above
Sensor Short
217°F (103°C).
Board is sensing flame when both
Flame w/o CFH
main and pilot valves are commanded
shut.
Pilot gas valve output is not in
PV Output Fault
commanded state.
Main gas valve output is not in
MV Output Fault
commanded state.
Internal Fault
Board fault, replace board.
Memory fault, reset set points,
EEPROM Fault
replace board if fault does not clear.
Time clock/fireman switch circuit is
Clock/Fireman Sw
open.
Low Temp
Water temperature below 36°F (2°C).
Lockout
Table L.
Heat Status Messages - Active Faults
Condition
Condition
The following conditions are displayed only while there is
a demand for heat present.
Display
Water Sw Open
Water pressure switch open.
Vent/Field
Vent spill switch/field switch #1 open.
Sw #1
Hi Limit 1 Fault
High limit 1 open.
Hi Limit 2 Fault
High limit 2 open.
Rollout Sw Open
Rollout switch open.
Field-supplied flow switch/field switch
Flow/Field SW #2
#2 open.
Alternating with "No pilot sensed" -
Pilot flame not established within the
Ignition Lockout
required time (15 sec or 90 sec).
(Propane Tab
Alternating with "Main Ign Failure"
Broken)
- Pilot flame lost during the 8 second
trial to ignite the main burner.
Ignition Failure
Alternating with "No pilot sensed" -
(Propane Tab Not
Pilot flame not established within 90
Broken)
seconds.
Alternating with "Main Ign Failure"
Ign 6min Delay
- Pilot flame lost 4 times within the 8
(Propane Tab Not
second trial to ignite the main burner.
Broken)
Heater will lockout for 6 minutes
before retrying.
Table M. Heat Status Messages - Demand for Heat
Condition
19