2.5 Applying Power

DC Power Terminal Block

For supporting power redundancy, the device is featured with two DC power input interfaces, DC input A and
input B that enable to receive power from two different power sources.
2.5.1 DC power Terminal Block
Connector: European 4P terminal block & plug
DC Power input contacts:
Redundant input A & B
A 
1
2
A +
Pin
B 
3
4
B +
DC power input voltages: +12 ~ +60VDC
Power consumption: 8.5W max. @24V
Power wires: 24 ~ 12AWG (IEC 0.5~2.5mm
Wire length: 1 meter max.
Protection: Polarity Reversal shutdown
DC power input A () terminal
+
DC power input A (
) terminal
DC power input B () terminal
+
DC power input B (
) terminal