Typical Installations; Fully Ducted System; Ully Ucted Ystem; Entral Raw Oint - Broan HRVH100S Installation Manual

High efficiency heat recovery ventilator
Hide thumbs Also See for HRVH100S:
Table of Contents

Advertisement

Available languages

Available languages

2. T
I
YPICAL
NSTALLATIONS
Use the following illustrations as guidelines to help you decide on how the unit will be installed.
All the units should be hung from the joists.
In every case, bathroom fans and a range hood could be used to exhaust stale air. Also, for homes with more than one level, we recommend
one exhaust register at the highest level.
There are 3 installation methods: Fully Ducted System, Central Draw Point and Simplified Installation.
NOTE: An electrical outlet has to be available within 3 feet of the unit.
2.1 F
D
S
ULLY
UCTED
YSTEM
Stale air coming from the register located at the highest level of the
house is exhausted to the outdoor. Fresh air from outdoor is filtered and
supplied by the register located in the lowest liveable level.
Homes with more than one level require at least one exhaust register at
the highest level.
See figure at right.
2.2 C
D
P
ENTRAL
RAW
Stale air coming from the register located at the highest level of the
house is exhausted to the outdoor. Fresh air from outdoor is filtered and
supplied to the return (plenum) or the supply duct of the forced air unit.
See figure at right.
For this type of installation, it is not essential that the forced air system
blower runs when the unit is in operation, but we recommend it.
NOTE: Home with multiple forced air systems should have one unit on
each system.
2.3 S
I
IMPLIFIED
NSTALLATION
Stale air is exhausted to the outdoor. Fresh air from outdoor is filtered
and supplied to the return (plenum) or the supply duct of the forced air
unit.
See figure at right.
To avoid cross-contamination and achieve the highest efficiencies, the
forced air system blower must always be ON.
NOTE: Home with multiple forced air systems should have one unit on
each system.
(P
RIMARILY FOR HOMES WITH RADIANT HOT WATER OR ELECTRIC BASEBOARD HEATING
(C
OINT
ONNECTION TO A FORCED AIR SYSTEM
(C
ONNECTION TO A FORCED AIR SYSTEM
VH0024
)
VH0025
)
VH0093
4
)

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ervh100s

Table of Contents