Service Data consist of the tank temperature as measured at two points in the tank and an indication as to which
probe(s) are making contact with the water. To view data, enter the service mode as noted above and advance to
the "Srv" screen. Use the left or right button to enter service data mode. Use the center button to advance through
the data. The table below list the data that is displayed.
Data displayed
Lower Temperature
Upper Temperature
Probes
Exit
* The 3 dashes indicate that the temperature value reported by the thermistor is outside the display range, 100-215F.
This could be because the tank is cold or because the thermistor is out of calibration. If the tank temperature is
within the noted range, the thermistor is defective and should be replaced.
User Mode is entered by holding any one of the buttons on the face of the machine while powering up the brewer.
Note that the user mode is also automatically entered whenever the calibration volume setting is changed. The
beverage volumes, brew time, and visa-brew time can be programmed for each of the three buttons on the face of
the brewer. The brew volume may all be run through the basket or a portion of the total volume may be added to the
brewed concentrate as cold water dilution. The brewer will determine the minimum brew time possible based on
pump speed and calibration values as outlined previously. This time is set as the default whenever calibration values
are changed. The brew time can be extended to lengthen the water delivery time to meet a specific beverage taste
profile. For coffee only machines, brew total and brew concentrate should match. The table below list the data
displayed and values available.
Data displayed
Screen
Example
Brew 1 Settings
b1
Brew 1 Total
64
Brew Volume
Brew 1 Concentrate
64
Volume
Brew 1 Time
3:30
Brew 1 delay
0:05
Visa-brew 1 Time
0:30
Brew 2 Settings
b2
Brew 2 Total
64
Brew Volume
Brew 2 Concentrate
64
Volume
Brew 2 Time
3:30
Brew 2 delay
0:05
Visa-brew 2 Time
0:30
Brew 3 Settings
B3
Brew 3 Total
84
Brew Volume
Brew 3 Concentrate
42
Volume
Brew 3 Time
3:30
Brew 3 delay
0:05
Visa-brew 3 Time
0:30
Exit
End
Screen
Values
Example
Available
198
N/A
.
20
0
N/A
1:L
L
End
N/A
Values
Available
N/A
Off, 30-128
30-Total Brew
Volume
Min-9:59
0-2:00
0:00-4:00
N/A
Off, 30-128
30-Total Brew
Volume
Min-9:59
0-2:00
0:00-4:00
N/A
Off, 30-128
30-Total Brew
Volume
Min-9:59
0-2:00
0:00-4:00
N/A
Comment
Degrees F, OPn, SHr, - - -*
Degrees F, OPn, SHr, - - -*
Displays L for liquid level if probes are in contact with the water.
Use left or right button when displayed to exit this mode.
Comment
Displays briefly to indicate that the parameters are for brew
button 1 (left)
Ounces. Button can be turned off and will serve as cancel only.
Program the volume of the total volume that should be delivered
as hot water through basket. Total - Conc = Cold Dilution.
Calculated minimum to 9 minutes and 59 seconds.
Delay between end of hot water delivery and start of cold water.
Only displays if Conc Volume < Total Volume and is > 0
Set to allow for beverage to finish dripping from basket after
water delivery time has been completed.
Displays briefly to indicate that the parameters are for brew
button 2 (center)
Ounces. Button can be turned off and will serve as cancel only.
Program the volume of the total volume that should be delivered
as hot water through basket. Total - Conc = Cold Dilution.
Calculated minimum to 9 minutes and 59 seconds.
Delay between end of hot water delivery and start of cold water.
Only displays if Conc Volume < Total Volume and is > 0
Set to allow for beverage to finish dripping from basket after
water delivery time has been completed.
Displays briefly to indicate that the parameters are for brew
button 3 (right)
Ounces. Button can be turned off and will serve as cancel only.
Program the volume of the total volume that should be delivered
as hot water through basket. Total - Conc = Cold Dilution.
Calculated minimum to 9 minutes and 59 seconds.
Delay between end of hot water delivery and start of cold water.
Only displays if Conc Volume < Total Volume and is > 0
Set to allow for beverage to finish dripping from basket after
water delivery time has been completed.
Use left or right button when displayed to exit this mode.
4
Man PN 121751 Rev 20170617