Loading And Updating Software Procedures - Frymaster FilterQuick FQG30 Service Manual

Gas fryer
Table of Contents

Advertisement

1.19

Loading and Updating Software Procedures

Updating the software takes approximately 30 minutes. The software only needs to be loaded in ONE controller and it
will update all the controllers and boards in the system. Typically this is done on the far left controller. To update the
software, follow these steps carefully:
1. Switch all controllers to OFF. Press the temperature button to check current controller/MIB/AIF/ATO
software versions.
2. Remove the bezel and remove the two screws on the left side cover plate of the controller board.
3. With the controller folded down, insert the SD card, with the contacts facing down and the notch on the
bottom right (see Figure 28 and 29), into the slot on the left side of the controller.
4. Once inserted, UPGRADE IN PROGRESS appears on the left display and WAIT on the right.
5. The display then changes to CC UPDATING on the left and the percentage completed appears on the right.
The display counts up to 100 on the right, changing to a flashing BOOT. DO NOT REMOVE THE CARD
UNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 8.
6. Then UPGRADE IN PROGRESS is displayed on the left display and WAIT on the right again
followed by COOK HEX, mib HEX, aIf HEX ending with aTO HEX displayed on the left and
the percentage complete on the right.
7. The display then changes to REMOVE SD CARD on the left and 100 on the right.
8. Remove the SD card using the fingernail slot on the top of the SD card.
9. Once the SD card is removed the display changes to CYCLE POWER.
10. Cycle the control power using the hidden reset switch behind the right control box. ENSURE THE
SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB
BOARD HAS FULLY RESET BEFORE CONTINUING.
11. When the update is complete the controller displays OFF. The MIB display will remain blank while
software is loading, changing to show the vat numbers. Once the LED's stop blinking, the MIB board will
display A.
12. Cycle the control power using the hidden reset switch behind the right control box again. ENSURE THE
SWITCH IS HELD FOR 10 SECONDS. WAIT ANOTHER 20 SECONDS UNTIL THE MIB
BOARD HAS FULLY RESET BEFORE CONTINUING.
13. With the controller displaying OFF, VERIFY software update by pressing the temperature button
to check updated Controller/MIB/AIF/ATO version on each controller. IF ANY BOARDS DID
NOT UPDATE, REPEAT THE PROCESS STARTING WITH STEP 3.
14. Press the temperature button again.
15. Press the EXIT button to escape.
16. Once the software has been updated and the versions are correct, replace the cover and screws covering the
SD card slot.
17. Reinstall the screws attaching the controllers and bezel by reversing steps 2 through 5.
Figure 28
1-56
Figure 29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents