Filterquick - Frymaster FilterQuick FQG30 Service Manual

Gas fryer
Table of Contents

Advertisement

Problem
Controller displays
IS VAT FULL?
YES NO after a
filter function.
Controller displays
IS VAT FULL?
YES NO during a
cook or in idle mode
with an audible alarm.
Controller displays
IS OIL SENSOR
CLEAM?
CONFIRM during a
cook or in idle mode
with an audible alarm.

1.18.2 FilterQuick

To enter any of the following codes: Press and hold the  button until Main Menu changing to Product
setup is displayed. Press  to scroll to Tech Mode and press the  button.
displayed. Enter a code number below to perform a function.
Clear E-Log, Clear Passwords, Change Lane Count, Change Hold Mode and Perform
High Limit Test, – Enter 3000.
Reset Factory Menu - Enter 3322. The controller display flashes and quickly counts from 1-40
and switches to off. (NOTE: This will delete any hand-entered menu items).
Change from F° to C° - Enter 1658. The controller displays off. Turn the controller on and
check temperature to see the temperature scale. If the desired scale is not displayed, repeat.
Reset RECOVERY FAULT CALL SERVICE – Enter 0042.
The following codes require the removal and reinsertion of the J3 locator plug on the rear of the controller before
entering the code.
Reset CALL TECH Message - Disconnect board locator plug (J3). Reinsert plug. Enter 1000.
Controller display switches to off. Remove and then restore power to the controller using the 20-pin
plug. If this error is displayed, replace the controller.
Probable Causes
A. An error has occurred due to carbon
buildup on oil level sensor. Normal
after some filter menu functions
when filling.
B. All the oil may not have returned
during a filter function due to dirty or
clogged filter paper, clogged filter
pump, filter pump thermal overload,
improperly installed filter pan
components, worn or missing O-
rings, cold oil or an actuator problem.
C. OIB relay ground issue.
A. An error has occurred due to carbon
buildup on oil level sensor.
B. OIB relay/time delay relay board ground
issue.
C. CAN communication issues, component
failure issues.
A. The oil level sensor may be coated with
caramelized oil.
B. OIB relay ground issue.
C. CAN communication issues, component
failure issues.
Controller Useful Codes
A. If answering yes directs to clean oil sensor,
clean oil level sensor with a scratch pad and
retry. Otherwise press  (YES) if the vat is
full, otherwise press  (NO) and follow
prompts.
B. Check to ensure that the probable causes are
remedied. Follow the prompts to refill the vat.
( Follow the steps in the flowchart in section
1.18.5.)
C. See item B in section below.
A. If answering yes directs to IS OIL SENSOR
CLEAN? CONFIRM, clean the oil level sensor
with a scratch pad and power cycle the
controller.
B. Check ground wire from OIB relay/time delay
relay board. If attached to interface board lug
mount stud, move the ground wire and attach it
to the stud on rear wall of component box, with
the ground wire from the 7 second time delay
relay board.
C. If the issue continues check software versions
to verify CAN communication. Check AIF
connections from AIF board J2 pin 9 DV or pin
10 FV to pin 3 of time delay relay board.
Check OIB relay/time delay relay board in
component box.
A. Clean sensor with scratch pad.
B. See item B in section above.
C. If the issue continues check software versions
to verify CAN communication. Check AIF
connections. Check OIB relay in component
box.
1-47
Corrective Action
ENTER CODE is

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents