Filterquick ™ Filter Error Flowchart - Frymaster FilterQuick FQG30 Service Manual

Gas fryer
Table of Contents

Advertisement

1.18.5 FilterQuick
Fryer returns
to cook mode
for 4 minutes
or 15 minutes
if paper
change
expired.
This chart follows the process of clearing
a filtration issue. The prompt is displayed
when any of the following occur:
1. a clogged filter paper,
2. a tripped or defective filter pump,
3. a leaky O-ring on the pick-up tube,
4. a failed drain valve/actuator, or
5. a failed return valve/actuator.
Filter Error Flowchart
NORMAL
OPERATION
RESUMES
SIXTH
CONSECUTIVE
FILTER ERROR
Change filter
paper and
ensure filter
pan is pulled
out for a
minimum of
30 seconds.
ANSWERING
NO 3X
If
the
controller
REQUIRED, the fryer can be used in most
cases by answering NO when the prompt for
SYSTEM ERROR FIXED? YES NO is
displayed. The message repeats every 15 minutes
until the issue is repaired and error cleared by a
answering YES when SYSTEM ERROR
FIXED? YES NO is displayed.
1-50
MESSAGE
DISPLAYED
Call an
Authorized
Repair
Technician
Fryer
returns to
cook mode
for 15
minutes.
displays
SERVICE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents