Frymaster FilterQuick FQG30 Service Manual page 14

Gas fryer
Table of Contents

Advertisement

Wiring connection
2. Remove the blower motor shield and separate the blower motor from the housing as shown in the
illustration below.
3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or detergent on the
blower wheel and the blower housing. Allow it to soak for five minutes. Rinse the wheel and housing with
hot tap water, then dry with a clean cloth.
The air pressure switch on the combustion blower should read: Full Vat units-122pa
(0.5 inches W.C.) and for Split Vat units-180pa (0.72 inches W.C.).
Wrap the motor and wires
with plastic wrap or a
4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor assembly and
blower housing. Reinstall the blower shield.
Blower assembly
mounting nuts
Remove these screws to
remove the shield from the
blower assembly.
NOTICE- Australia Only
plastic bag.
Remove these nuts to
separate the blower
motor from the housing.
Blower Wheel
1-9
Blower Housing

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents