Stanley Argon F500 OVAL Installation And Operating Instructions Manual page 10

Table of Contents

Advertisement

Fig.5
Fig.7
Terminal Position
A* Directly below an opening, air brick,
opening window etc.
B
Above an opening, air brick, opening win-
dow etc.
C
Adjacent to an opening, air brick, open-
ing window etc.
D
Below gutters, soil pipes or drain pipes
E
Below eaves
F
Below balconies of car port roof
G
From a vertical drain pipe or soil pipe
H
From an internal or external corner
* In addition, the terminal should not be nearer than 300mm to an opening in the building fabric formed for the purpose of
accommodating a built in element such as a window frame.
Fig.6
Distance
Terminal Position
(mm)
600
I
Above ground roof or balcony level
300
J
From a surface facing the terminal
400
K
From a terminal facing the terminal
300
L
From an opening in the car port (e.g.
door, window into the dwelling)
300
M
Vertically from a terminal on the same
wall
600
N
Horizontally from a terminal on the same
wall
300
P
From a vertical structure on the roof
600
Q
Above intersection with roof
10
Distance
(mm)
300
600
600
1200
1500
300
600
150