sectIon 3
3.0 torch Mounting
cautIon
torch Mounting options.
The torch is normally mounted by the sleeve. Do not cover vent hole. For custom alternative mounting, the torch
can be mounted by the collar shown. This insulated collar and its shoulder are machined relative to the nozzle
retainer thread on the torch body. Use only specified mounting surfaces.
collar
Vent hole
Do not cover Vent hole.
When mounting, do not to cover the small vent hole in the side of the sleeve.
this hole allows coolant to drain from inside the sleeve should a leak occur in a
service line.
1
sleeve
InstallatIon